Every prior std79-doe.fth run's automatically-extracted CSV
(scripts/extract_doe.sh) was silently empty -- g_doe_log_enabled
(doe_log.c) defaults off, and nothing in the campaign ever called HB-ON.
EXEC-STD79-DOE now calls HB-ON right before its trial loop and HB-OFF
right after, so the per-heartbeat-tick physics/timing CSV (18 columns:
tick_number, hot_word_count, avg_word_heat_q48, apic_ticks, per-VM
heat_q48, etc.) finally covers the run's own window on all three
architectures.
Found and fixed two bugs along the way, one in a comment and one in the
ad hoc QEMU orchestration script used to drive these runs (not part of
this repo):
- std79-doe.fth's own explanatory comment accidentally spelled out the
literal "[HADES][DOE ]" tag string doe_log.c prefixes each row with --
the FORTH REPL's compile-time echo of that comment then matched
scripts/extract_doe.sh's own extraction grep, corrupting the first
extracted CSV row with comment text instead of real telemetry. Fixed by
never spelling out the literal substring.
- The harness script's completion-detection watched for "STD79-DOE:
complete" anywhere in the log since before the whole capsule was fed,
which matches the colon definition's own compile-time echo of that same
string literal, not just the real end-of-run print. Without HB-ON the
entire 27-trial run finished in a few seconds -- faster than one poll
interval -- so the false match and the real one always landed in the
same window and this never surfaced. HB-ON's added per-tick console I/O
slowed real execution enough to expose it: the script sent BYE the
moment compilation finished, truncating every trial after whatever
point compilation had reached (aarch64 lost 9 of 27 trials this way on
the first attempt). Fixed by feeding definitions and invocation as two
genuinely separate connections, with the completion-watch window opened
only after compilation is confirmed landed.
Verified 27/27 trials correct on every architecture via the campcampaign's
most distinctive result markers (both M*/M/MOD 18-19 digit values and the
2147483648 2/ result, all exactly 27 occurrences, zero faults) rather than
exact substring reconstruction: HB-ON's async per-tick CSV printer and the
trial loop's own console output share the same serial line with no
locking, so CSV rows can splice mid-token into trial output on the wire
(confirmed live -- cosmetic only, the underlying FORTH execution and
values are unaffected). results-20260912-with-heartbeat-csv/ holds both
the raw logs and their paired heartbeat CSVs; the earlier truncated runs'
logs are kept too (never delete logs) as the record of how this was found.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01EXieurDfDSsDFdnSyusuWo